Compressor selection
Catalog models that deliver the required flow at your pressure. The closest by capacity are at the top.
| Model | Series | m³/min | bar | kW | Margin | Request |
|---|---|---|---|---|---|---|
| ESC-25B | ESC | 3 | 8 | 18.5 | +0 % | |
| ESK-25D | ESK | 3 | 8 | 18.5 | +0 % | |
| ALPINA 37 Voil-free | ALPINA | 3 | 8 | 27.5 | +0 % | |
| ALPINA 37 Foil-free | ALPINA | 3 | 8 | 27.5 | +0 % | |
| AURORA 30-10 | AURORA | 3.21 | 10 | 22 | +7 % | |
| EVA-X-22 | EVA-X | 3.3 | 8 | 22 | +10 % | |
| EVA-X-22 VSD | EVA-X | 3.3 | 8 | 22 | +10 % | |
| EVA-X-22-8-500 | EVA-X stations | 3.3 | 8 | 22 | +10 % | |
| EVA-X-22-8-500RD | EVA-X stations | 3.3 | 8 | 22 | +10 % | |
| DELIA 30oil-free | DELIA | 3.3 | 8 | 22 | +10 % | |
| ESC-30X | ESC-X | 3.59 | 8 | 22 | +20 % | |
| ESC-30X VSD PM | ESC-X | 3.59 | 8 | 22 | +20 % | |
| ESC-30X-500 | ESC-X stations | 3.59 | 8 | 22 | +20 % | |
| ESC-30X-500 VSD PM | ESC-X stations | 3.59 | 8 | 22 | +20 % | |
| ESC-30X-500A | ESC-X stations | 3.59 | 8 | 22 | +20 % | |
| ESC-30X-500A VSD PM | ESC-X stations | 3.59 | 8 | 22 | +20 % | |
| EVA-22-8 | EVA | 3.6 | 8 | 22 | +20 % | |
| ESK-30D | ESK | 3.6 | 8 | 22 | +20 % | |
| ALPINA 45 Voil-free | ALPINA | 3.6 | 8 | 33 | +20 % | |
| ALPINA 45 Foil-free | ALPINA | 3.6 | 8 | 33 | +20 % | |
| AURORA 30-8 | AURORA | 3.8 | 8 | 22 | +27 % | |
| AURORA DSH 30-10 | AURORA DSH | 3.8 | 10 | 22 | +27 % | |
| AURORA 40-12,5 | AURORA | 3.93 | 12.5 | 30 | +31 % | |
| EVA-X-DUO-22 | EVA-X DUO | 4.1 | 8 | 22 | +37 % | |
| EVA-X-DUO-22 VSD | EVA-X DUO | 4.1 | 8 | 22 | +37 % | |
| AURORA DSH 30-8 | AURORA DSH | 4.2 | 8 | 22 | +40 % | |
| ALPINA 50 Voil-free | ALPINA | 4.2 | 8 | 38.5 | +40 % | |
| ALPINA 50 Foil-free | ALPINA | 4.2 | 8 | 38.5 | +40 % | |
| AURORA 40-10 | AURORA | 4.45 | 10 | 30 | +48 % | |
| ESC-40X | ESC-X | 4.5 | 8 | 30 | +50 % | |
| DELIA 40oil-free | DELIA | 4.8 | 8 | 30 | +60 % | |
| DELIA 40 Woil-free | DELIA | 4.8 | 8 | 30 | +60 % | |
| ALPINA 60 Voil-free | ALPINA | 4.8 | 8 | 44 | +60 % | |
| ALPINA 60 Foil-free | ALPINA | 4.8 | 8 | 44 | +60 % | |
| EVA-30-8 | EVA | 5 | 8 | 30 | +67 % | |
| EVA-X-30 | EVA-X | 5 | 8 | 30 | +67 % | |
| ESC-40B | ESC | 5 | 8 | 30 | +67 % | |
| ESK-40D | ESK | 5 | 8 | 30 | +67 % | |
| AURORA 50-12,5 | AURORA | 5.07 | 12.5 | 37 | +69 % | |
| AURORA 40-8 | AURORA | 5.2 | 8 | 30 | +73 % | |
| ALPINA 67 Voil-free | ALPINA | 5.4 | 8 | 49.5 | +80 % | |
| ALPINA 67 Foil-free | ALPINA | 5.4 | 8 | 49.5 | +80 % | |
| AURORA 50-10 | AURORA | 5.69 | 10 | 37 | +90 % | |
| DELIA 50oil-free | DELIA | 6 | 8 | 37 | +100 % | |
| DELIA 50 Woil-free | DELIA | 6 | 8 | 37 | +100 % | |
| ALPINA 75 Voil-free | ALPINA | 6 | 8 | 55 | +100 % | |
| ALPINA 75 Foil-free | ALPINA | 6 | 8 | 55 | +100 % | |
| EVA-X-37 | EVA-X | 6.05 | 8 | 37 | +102 % | |
| EVA-X-37 VSD | EVA-X | 6.05 | 8 | 37 | +102 % | |
| ESC-50B | ESC | 6.2 | 8 | 37 | +107 % | |
| ESK-50D | ESK | 6.2 | 8 | 37 | +107 % | |
| AURORA 60-12,5 | AURORA | 6.21 | 12.5 | 45 | +107 % | |
| ESC-50X | ESC-X | 6.28 | 8 | 37 | +109 % | |
| ESC-50X VSD PM | ESC-X | 6.28 | 8 | 37 | +109 % | |
| AURORA 50-8 | AURORA | 6.8 | 8 | 37 | +127 % | |
| AURORA DSH 50-10 | AURORA DSH | 6.8 | 10 | 37 | +127 % | |
| ESC-60B | ESC | 7 | 8 | 45 | +133 % | |
| ESK-60D | ESK | 7 | 8 | 45 | +133 % | |
| DELIA 60oil-free | DELIA | 7 | 8 | 45 | +133 % | |
| DELIA 60 Woil-free | DELIA | 7 | 8 | 45 | +133 % |
Selection calculations
To select equipment we need four parameters. If you don’t have some of them, we will help determine them on site.
- Air flowHow many m³/min the equipment consumes at peak load.
- PressureWorking pressure in the network: 8, 10, 13, 16 bar or higher.
- Purity classRequirements for particles, moisture and oil per ISO 8573-1.
- Installation conditionsRoom, temperature, power supply, existing receiver.
Air receiver sizing
Minimum volume at which a rotary screw compressor switches between load and unload no more than once every 30 seconds.
V = 0.25 · q · p₁ · T₀ / (f · Δp · T₁), where q is the capacity in L/s, p₁ = 1 bar, T₁ = 303 K and T₀ = 313 K are the inlet and receiver temperatures, f is at most 1 cycle per 30 s, Δp is the pressure difference. Method: Atlas Copco Compressed Air Manual. If the line has short peak demands above the compressor capacity, the volume is calculated separately – our engineer will take this into account.
Compressed air purity classes
| Class | Particles, µm | Dew point, °C | Oil, mg/m³ |
|---|---|---|---|
| 1 | 0.1 | −70 | 0.01 |
| 2 | 1 | −40 | 0.1 |
| 3 | 5 | −20 | 1 |
| 4 | 15 | +3 | 5 |
| 5 | 40 | +7 | 25 |
The class is written as three digits: particles, moisture, oil. For example, 1.4.1 means particles up to 0.1 µm, dew point +3 °C, oil up to 0.01 mg/m³. A +3 °C dew point is provided by refrigerated dryers, −20…−70 °C by desiccant dryers.