Compressed air solutions for your business

+7 (925) 578-76-70Mon–Fri, 9:00–18:00 Moscow time
RU

Oxygen generator, OXIA series

OXIA 110

Twin-tower oxygen generator

  • 110Oxygen capacity, Nm³/h
  • 0.4–0.6Inlet air pressure, MPa
  • 0.2Power, kW
  • 93±2Oxygen purity, %

Technical specifications

Oxygen capacity, Nm³/h
110
Compressed air consumption, Nm³/min
23.83
Power, kW
0.2
Inlet
DN65
Outlet
Rp 1-1/2
Dimensions, mm (L×W×H)
2700×1600×3400
Weight, kg
4800±100
Air receiver upstream of generator
2.5 m³ / 0.8 MPa
Oxygen receiver downstream of generator
2.5 m³ / 0.8 MPa
Oxygen purity, %
93±2
Voltage, V
220
Inlet air pressure, MPa
0.4–0.6
Oxygen pressure, MPa
0.3–0.5
Inlet air dew point, °C
−70…−40
Inlet air temperature, °C
+1…+35
Max. ambient temperature, °C
45
Noise level, dBA
80

Oxygen purity depends on flow: 1 Nm³/h of oxygen at 95 % requires 14 Nm³/h of compressed air, at 93 % – 12, at 90 % – 11, at 88 % – 10.

Specifications are provided by the manufacturer and are confirmed when ordering.

About the OXIA series

PSA generators producing 10–200 Nm³/h of oxygen at 93±2 % purity. Two molecular sieve towers work alternately for uninterrupted supply.

All OXIA models in a comparison table
Call